Airvent SM HY is a surface mounted humidity sensitive window vent. It i san Energy saving solution for residential, commercial and public utilities (e.g. schools, hospitals). The airvent SM HY can be applied in all ventilation systems, the operation of which is based on passive air supply devices.
DG Standard
A durable, robust and cost effective Glazed In vent, suitable for a wide range of applications.
The basic glazed in vent. Simple and effective. Aluminium body with uPVC hood.
The DG standard is a durable, robust and cost effective Glazed In vent, suitable for a wide range of applications. Core features include:
- Insect Grill
- Aluminium Construction (vent body)
- uPVC Hood
- Polyester Powder Coated
- 10 Year Guarantee
The DG Standard is available in a wide range of size and colour options to suit your specific project needs.
COLOURS
White (HIPCA) "Satin" | Mill Finish |
Black RAL 9005 "Satin" | Bespoke Colours and Finishes Available |
Choose from our stocked off-the-shelf range or indeed create something a little more bespoke.
- Manual control
- Cord control (right or left hand)
- Bespoke sizes
- Bar length
- Upward deflector
- Fully controllable ventilation
- Concealed trickle ventilation
- Permanently open ventilation
- Aluminium hood
Airflow guide
Glass Width | Option | Equivalent Area / Metre | Length for 2500 EA | Length for 5000 EA | Geometric Open Area / Metre |
---|---|---|---|---|---|
24mm | DG Standard (Fully Controllable) | 5293 | 472mm | 945mm | 6387 |
24mm | DG Standard (Fully Controllable & Upward Deflector) | 4841 | 516mm | 1033mm | 6387 |
24mm | DG Standard (Concealed Trickle) | 5475 | 457mm | 913mm | 6769 |
24mm | DG Standard (Concealed Trickle & Upward Deflector) | 5111 | 489mm | 978mm | 6769 |
28mm | DG Standard (Fully Controlable) | 5338 | 468mm | 937mm | 6387 |
28mm | DG Standard (Fully Controllable & Upward Deflector) | 4790 | 522mm | 1044mm | 6387 |
28mm | DG Standard (Concealed Trickle) | 5385 | 464mm | 929mm | 6769 |
28mm | DG Standard (Concealed Trickle & Upward Deflector) | 5141 | 486mm | 973mm | 6769 |
Acoustics
Under normal conditions the airvent DG Standard achieved the following Sound Reduction results:
Position | Acoustic Detail |
---|---|
FULLY OPEN (Normal Operation Mode) | Up to 30 db Dnt Rw Up to 30 db Dne W |
CLOSED (Concealed Trickle) | Up to 37 db Dnt Rw Up to 36 db Dne W |
CLOSED | Up to 40 db Dnt Rw Up to 40 db Dne W |
Acoustic test data available upon request. |